Digital Keypad Motorised Safe Lock for Hotel Room Safe

Material: Zinc Alloy
Type: Electronic
Style: European
Shape: Finishing Up Lock
Anti-theft Standard: B
Part: Lock
Samples:
US$ 50/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
E-845JD
Backset
60mm
Door Thickness Fits
35-50mm
Lock Cylinder Length
65mm
Usage
Household Door Locks, Bedroom, Channel Lock
Locking Mechanism
Motorized Locking System
User Code
3-6 Digits
Sea Port
Ningbo China
Display
LCD Display
Illuminated Keypad
Yes
Master Key
2 PCS Cross Keys
Interior Light
Option
Power
4AA Batteries
Button
Blue Illuminated Keypad Button
Logo
Customized
Audit Trail
100 PCS
Interior Socket
Option
Opening
Right Hand Opening
Handleheld Device
Ceu
Low Battery Warning
Yes
Transport Package
Export Standardfoams Carton
Specification
CE&ROHS
Trademark
YOSEC
Origin
China
HS Code
830140000
Production Capacity
50000 PCS Per Month

Product Description

YOSEC latest design hotel safe lock E-845JD Main feature:

Electronic hotel safe lock with chromed keypad frame
Illuminated keypad button with blue color is easy to operate the safe in dark

Motorized locking system with 2 locking bolts
3-6 digits user code and master code can be reset
Last 100 pcs opening records can be read and printed out
2 pcs star cross key as override key for emergency 
Factory default codes can be reset by micro-switch
Time and date can be reset by press button on keypad
Item name Electronic hotel safe lock
Model No E-845JD
Codes user code , master code(3-6digits)
Opening memory 100-500 pcs opening and closing records
Handheld device CEU ( connect safe and computuer )
Override key 2 pcs(star key)
Baklit keypad 0-9 press buttons (including CLEAR and LOCK button
Warranty 1 year

Hotel room safe stype lock with soft keypad button and LED display
Digital Keypad Motorised Safe Lock for Hotel Room Safe

New design electronic safe lock for hotel safes with motorized locking mechanism
Digital Keypad Motorised Safe Lock for Hotel Room Safe

Red or blue color display for customer to choose
Digital Keypad Motorised Safe Lock for Hotel Room Safe

Different kinds of digital safe lock to be selected for safe manufacture 
Digital Keypad Motorised Safe Lock for Hotel Room Safe

100pcs opening records can be read and printed out by CEU to connect with safe and computuer
Digital Keypad Motorised Safe Lock for Hotel Room Safe
Master key can be alike/safe key to open all hotel in room safe or can be diifferent key (which measn one key open one laptop size hotel safe)
Digital Keypad Motorised Safe Lock for Hotel Room Safe
CEU to connect with safe to read opening records, it can show who opened the hotel safe , user opened or hotel manager opened , or opened by mechanical override key , then CEU will connect with computer to download the opening records and printed out by printer machine.

Note: The keypad is ready when the screen display "GOOD" after power on.
1. User code instruction
1) Lock by user code
When the door is unlocked, input any 3 to 6 digits code and press "#" button to lock.
2) Unlock by user code (Factory code 123456)
When the door is locked, input the correct digits code to unlock and keypad
displays "OPEN". If the code is incorrect, keypad dispalys "ERROR".
Note:
1) The unlock code is the last code that locks the door.
2) If entering incorrect code for 4 times, the keypad will be locked for 15 minutes.
2. Master code instruction
1) Unlock with master code (Factory code 000000)
When the door is locked, quickly press "#" 2 times, and screen displays "SUPER".
Then, input the correct master code to unlock, and screen displays "OPEN". If the
code is incorrect, keypad dispalys "ERROR".
2) How to change master code
When the door is unlocked
a. Press "* " 2 times, screen displays "-PROG-";
b. Input code "185015" + "#", screen displays "NEW";(Enter new master code in
10 seconds)
c. Input a new 6 digits code + "#", screen displays "AGAIN";
d. Re-enter the new code + "#", screen displays "GOOD". Master code change
complete.
3. How to read the lock operation record
200 lately records are able to read.
When the door is unlocked, press "*" 2 times + code"264580" + "#", then screen
displays "RECORD" to enter lock operation record reading mode. The record displays
in 4 screens. Function code as follows:
1) Press "2" for previous opening record;
2) Press "8" for next opening record;
3) Press "4" for previous screen;
4) Press "6" for next screen;
5) Press "*" to exit opening record reading mode.
Screen display instructions on lock operation record readings mode
First screen shows the record number and operation ways.
For example, screen displays "A001EU". A001 means record number 1, EU means
unlock by user code.
Operation code listed as follows:
EU ------ Unlock by use code
EL ------ Lock by user code
PU ------ Unlock by master code
UU ------ Unlock by CEU
OU ------ Unlock by reset button
OL ------ Lock by reset button
Second screen shows the date of that record. 6 numbers for year, month and day.
For example, "171116" means 16th, Nov, 2017
Third screen shows the time of that record. It only shows hour and minute.
For example, "13- -04" means 01:04 pm.
Fourth screen shows lock code or opration code.
When the record is an unlock operation, it shows lock code (user code or master
code) or unlock ways that is not by code ( UU or OU).
When the record is lock operation, it shows operation code (EL or OL)
4. How to set time
When the door is unlocked,
1) Press "* " 2 times, screen displays "-PROG-";
2) Input code "501508" + "#", screen displays "-DATA-";
3) Wait for lights "-DATA-" off, and screen shows date configuration. The number that
flashes is the data that you are going to input. For example, input "171116" to set
the date to 16th, Nov, 2017. After all numbers set, press "#" to next screen.
4) Now, screen shows time configuration. The number that flashes is the data that
you are going to input. For example, input "13- -04" to set the time to 01:04 pm.
After all numbers set, press "#" to finish the set. Screen shows "GOOD" and the
time set is complete.
5. Root configuration
NOTE: IF UNNECESSARY, WE DO NOT SUGGEST USER TO SET BELOW
CONFIRURATION.
Press "*" 2 times, screen shows "-PROG-", then enter code "156899" + "#". Screen
shows "-SET-", now the lock is in root configuration.
1) Screen 1, below is default setting.
1 0 0 1 2 0
position 1 2 3 4 5 6
Settings:
a. Position 1: Code display when unlocking
Enter "1" --- Screen displays code when entering it.
Enter "0" --- Screen does not display code when entering it. Each digits is
replaced by "o". Neither does the screen display the code when locking.
b. Position 2: Code flashes after locked
Enter "0" --- Screen does not flash code after locked.
Enter "1" --- Screen flashes code after locked. Note: If press "*" first, then you
enter the code and end with "#", screen does not flash the code.
c. Position 3: N/A.
d. Position 4: Enable or disable lock operation record function
Enter "0" --- Enable lock operation record function
Enter "1" --- Disable lock operation record function
e. Position 5: Options of locking ways
Enter "1" --- Home mode.
Now cut off the power and reload. Input a new user code and end with "#", then
the door is locked and user code is set. Now every time you input the user code
you need to end with "#" to lock and the user code is unchagable. Only power off
the lock under unlocked state can change the code. When locking it, you only
need to press "#".
Enter "2" --- Hotel mode.
When locking it, you need to input a code and end with "#". And you unlock it
with the last code you put. The code is changable every time.
f. Position 6: N/A
Press "#" to enter screen 2.
2) Screen 2: Below is default setting
4 7 1 5 1 0
Position 1 2 3 4 5 6
a. Position 1: Incorret input times setting for keypad locking
Enter number 1 to 9 to set the times of incorrect input before the keypad locks.
b. Position 2: Code digits setting
Enter "3" --- 3 digits code only
Enter "4" --- 4 digits code only
Enter "5" --- 5 digits code only
Enter "6" --- 6 digits code only
Enter "7" --- 3 to 6 digits code
c. Position 3 and 4: Keypad locking time after incorrect input
Enter "00" to "99" to set keypad locking time. Unit: minutes
d. Position 5: Master code enable setting
Enter "0" --- Disable master code
Enter :1: --- enable master code
e. Position 6: N/A
6. Reset the code to default setting
Remove the door back panel first. Find the black round "reset" button on the
mainboard, held the button until rest of the operation finished. After a few seconds you
will see the screen displays "OPENED". Then press "#" and screen displays "RESET".
Now the reset is done and you can release the reset button.
After reset, user code is "123456", master code is "000000", serial number is "0000",
7. Battery detection
When locked, press "#" once for battery detection.
"HI-BAT" means nomal.
"LO-BAT" means low battery, you need to change battery.
Undervoltage Value: 4.5V ± 0.2V
8. Parameter
Working voltage: 4 - 6 V
Working current: <150mA
Standby power comsuption: <30μA
 
Digital Keypad Motorised Safe Lock for Hotel Room Safe


Digital Keypad Motorised Safe Lock for Hotel Room Safe
CE certification is approved by NINGBO YOSEC SAFE
We have collected some of the most commonly asked questions submitted by our customers. If your questions are not answered

here, please feel free to Contact Us.

Sample: How could I get a sample?
     We have to charge sample fee, but we will return this fee to you in future bulk order.
Price: could I get your price list?
     Yes, please inform us the products (with model number, quantity ), then we will offer you a quotation by e-mail.
Shipment: what's the deliver date?

      25-30 days after we received your payment and confirmation

 MOQ: How much the MOQ?

      one 20 feet container,can be merged shipment

Payment Terms: How we arrange payment? 
     T/T or L/C At sight

Placing order: how to place an order.

    Email order details to Sales Department including items model number, quantity, destination port , selling countries, consignee's
   contact information including detail address and phone fax number and email address, notify party, etc.

Can you arrange the transportation for us?
Yes. We can arrange sea, air and courier transportation




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory
Plant Area
501~1000 square meters
Management System Certification
ISO 9001, OHSAS/ OHSMS 18001